Standard Permanent Magnet Coupling

Permanent magnet driving applies electromagnetic induction principle in Physics:
Moving conductors cut magnetic induction lines to produce induction current. The induction current in turns produces induced magnetic field. The interaction between induced magnetic field and permanent magnetic field produces force.
Advantages:
1. No physical connection, better soft start;
2. No refueling, no power supply, no maintenance required;
3. Isolated vibration transfer, so extend equipment life;
4. Tolerance allowable, easy to install and disassemble;
5. Simple and reliable in structure, suitable for harsh environment.
Application: Buceket Elevator, ChainConveyor, Belt Conveyor, Scraper, etc.
Model Selection Table for DYT-B Standard Permanent Magnet Coupling
MODEL |
POWER (1500rpm) |
POWER(1000rpm) |
DYT-B15 |
15KW |
11KW |
DYT-B30 |
30KW |
22KW |
DYT-B45 |
45KW |
30KW |
DYT-B75 |
75KW |
45KW |
DYT-B90 |
90KW |
75KW |
DYT-B132 |
132KW |
90KW |
DYT-B160 |
160KW |
132KW |
DYT-B200 |
200KW |
160KW |
DYT-B250 |
250KW |
200KW |
DYT-B355 |
355KW |
250KW |
DYT-B400 |
400KW |
355KW |
DYT-B450 |
450KW |
400KW |
DYT-B630 |
630KW |
450KW |
DYT-B800 |
800KW |
630KW |
DYT-B1250 |
1250KW |
800KW |
DYT-B2000 |
2000KW |
1250KW |
DYT-B2600 |
2600KW |
2000KW |
DYT-B3000 |
3000KW |
2600KW |
Before selecting model, please provide technical parameters of motor and load including motor power, speed, load shaft power, install dimension, ambient temperature and other parameters related to PM coupling’s characteristics. Then the correct model will be confirmed by DYT engineer.